49 lines
2.0 KiB
Markdown
49 lines
2.0 KiB
Markdown
# Geiger-interface
|
||
|
||
### GMC.MAP integration
|
||
- Create account on https://www.gmcmap.com/
|
||
- Login, go to **My Account** -> **Manage Geiger Counter**
|
||
- Go to **Add device**, select location on map, select your model -> **OTHER**
|
||
After that you will see **Account ID** and **Geiger Counter ID**
|
||
|
||
### HomeAssistant integration
|
||
After MQTT is configured in Geiger-interface, simply add to HomeAssistant configuration.yaml
|
||
|
||
```yaml
|
||
- name: "Geiger CPM"
|
||
state_topic: "esp32/CPM"
|
||
unit_of_measurement: "CPM"
|
||
icon: mdi:radioactive
|
||
- name: "Geiger μSv/h"
|
||
state_topic: "esp32/uSv"
|
||
unit_of_measurement: "μSv/h"
|
||
icon: mdi:radioactive
|
||
```
|
||
|
||
reload configuration and voilà!
|
||
|
||
<img src="assets/ha1.png" width="600"><br>
|
||
<img src="assets/ha2.png" width="600">
|
||
|
||
### RadMon integration
|
||
**TBD**
|
||
|
||
### J3x5 Tube specification
|
||
| Property | J3x5 |
|
||
|--------------------------------------------|--------------------------------------|
|
||
| Radiation type | beta, gamma |
|
||
| Dimensions (max), mm | d11 x 107 |
|
||
| Country of Origin | China |
|
||
| Vendor’s calibration<br>radioactive source | Co-60 |
|
||
| Sensitivity | 44 CPS at 1 mR/h<br>Co-60 |
|
||
| Dead Time | 180 microseconds* |
|
||
| At the background level | 25 pulses/minute |
|
||
| Internal background <br>noise | 0,2 pulses/s<br>12 pulses/minute |
|
||
| Recommended operating<br>supply voltage | glass tube 380 V<br>metal tube 400 V |
|
||
|
||
> *Dead Time for J305 based on the data from the Internet, since the datasheets from suppliers do not contain this data.
|
||
|
||
### Resources
|
||
- https://iot-devices.com.ua/
|
||
- https://www.gmcmap.com/
|
||
- https://radmon.org/ |