2.0 KiB
2.0 KiB
Geiger-interface
GMC.MAP integration
- Create account on https://www.gmcmap.com/
- Login, go to My Account -> Manage Geiger Counter
- Go to Add device, select location on map, select your model -> OTHER After that you will see Account ID and Geiger Counter ID
HomeAssistant integration
After MQTT is configured in Geiger-interface, simply add to HomeAssistant configuration.yaml
- name: "Geiger CPM"
state_topic: "esp32/CPM"
unit_of_measurement: "CPM"
icon: mdi:radioactive
- name: "Geiger μSv/h"
state_topic: "esp32/uSv"
unit_of_measurement: "μSv/h"
icon: mdi:radioactive
reload configuration and voilà!
RadMon integration
TBD
J3x5 Tube specification
| Property | J3x5 |
|---|---|
| Radiation type | beta, gamma |
| Dimensions (max), mm | d11 x 107 |
| Country of Origin | China |
| Vendor’s calibration radioactive source |
Co-60 |
| Sensitivity | 44 CPS at 1 mR/h Co-60 |
| Dead Time | 180 microseconds* |
| At the background level | 25 pulses/minute |
| Internal background noise |
0,2 pulses/s 12 pulses/minute |
| Recommended operating supply voltage |
glass tube 380 V metal tube 400 V |
*Dead Time for J305 based on the data from the Internet, since the datasheets from suppliers do not contain this data.