# Geiger-interface
### GMC.MAP integration
- Create account on https://www.gmcmap.com/
- Login, go to **My Account** -> **Manage Geiger Counter**
- Go to **Add device**, select location on map, select your model -> **OTHER**
After that you will see **Account ID** and **Geiger Counter ID**
### HomeAssistant integration
After MQTT is configured in Geiger-interface, simply add to HomeAssistant configuration.yaml
```yaml
- name: "Geiger CPM"
state_topic: "esp32/CPM"
unit_of_measurement: "CPM"
icon: mdi:radioactive
- name: "Geiger μSv/h"
state_topic: "esp32/uSv"
unit_of_measurement: "μSv/h"
icon: mdi:radioactive
```
reload configuration and voilà!

### RadMon integration
**TBD**
### J3x5 Tube specification
| Property | J3x5 |
|--------------------------------------------|--------------------------------------|
| Radiation type | beta, gamma |
| Dimensions (max), mm | d11 x 107 |
| Country of Origin | China |
| Vendor’s calibration
radioactive source | Co-60 |
| Sensitivity | 44 CPS at 1 mR/h
Co-60 |
| Dead Time | 180 microseconds* |
| At the background level | 25 pulses/minute |
| Internal background
noise | 0,2 pulses/s
12 pulses/minute |
| Recommended operating
supply voltage | glass tube 380 V
metal tube 400 V |
> *Dead Time for J305 based on the data from the Internet, since the datasheets from suppliers do not contain this data.
### Resources
- https://iot-devices.com.ua/
- https://www.gmcmap.com/
- https://radmon.org/