Geiger-interface

GMC.MAP integration

  • Create account on https://www.gmcmap.com/
  • Login, go to My Account -> Manage Geiger Counter
  • Go to Add device, select location on map, select your model -> OTHER After that you will see Account ID and Geiger Counter ID

HomeAssistant integration

After MQTT is configured in Geiger-interface, simply add to HomeAssistant configuration.yaml

    - name: "Geiger CPM"
      state_topic: "esp32/CPM"
      unit_of_measurement: "CPM"
      icon: mdi:radioactive
    - name: "Geiger μSv/h "
      state_topic: "esp32/uSv"
      unit_of_measurement: "μSv/h"
      icon: mdi:radioactive

reload configuration and voilà!


J3x5 Tube specification

Property J3x5
Radiation type beta, gamma
Dimensions (max), mm d11 x 107
Country of Origin China
Vendors calibration
radioactive source
Co-60
Sensitivity 44 CPS at 1 mR/h
Co-60
Dead Time 180 microseconds*
At the background level 25 pulses/minute
Internal background
noise
0,2 pulses/s
12 pulses/minute
Recommended operating
supply voltage
glass tube 380 V
metal tube 400 V

*Dead Time for J305 based on the data from the Internet, since the datasheets from suppliers do not contain this data.